Welcome! This guide details the Fluke 87 multimeter‚ offering complete operating instructions found within the 87 V/AN Users Manual; It’s a 38-page PDF resource.
The Fluke 87 Multimeter represents a robust and reliable tool designed for electrical professionals. This guide serves as a comprehensive resource for understanding its functions and capabilities‚ drawing from the official 87 V/AN Users Manual. It’s built to withstand demanding field conditions‚ offering accurate measurements for voltage‚ current‚ and resistance.
This multimeter has been rigorously tested and designed according to IEC Publication 348‚ ensuring safety requirements for electronic measuring apparatus are met. Compliance with IEC-1010 Category III‚ with a 1000V fuse rating‚ further underscores its safety features. Whether you’re a seasoned electrician or new to electrical testing‚ this manual will help you maximize the Fluke 87’s potential.
Accessing the Fluke 87 Service Manual (available as a PDF) provides detailed schematics and technical information for repair and maintenance. This introduction sets the stage for a thorough exploration of this versatile instrument.
Understanding the Fluke 87 Series
The Fluke 87 series‚ encompassing models like the 83‚ 85‚ and 87‚ represents a lineage of dependable digital multimeters. These instruments share a core design philosophy focused on durability and precision‚ adhering to IEC 348 safety standards. While specific features may vary between models‚ the fundamental operating principles remain consistent.
The Fluke 87-89 Series IV (PN 676137 5-99) builds upon this foundation‚ offering enhanced capabilities. Understanding the series as a whole allows for easier troubleshooting and component interchangeability‚ particularly when referencing the Fluke_83_85_87_Service_Manual.pdf. This shared architecture simplifies maintenance and repair procedures.

The series is known for its robust construction and reliable performance in challenging environments. Access to the service manual‚ a 108-page PDF‚ is crucial for in-depth understanding and repair‚ offering schematics and technical details.
Key Features and Specifications

The Fluke 87 series multimeters boast a comprehensive set of features designed for professional use. Key among these is compliance with IEC-1010 Category III‚ 1000V fuse ratings‚ ensuring user safety. The instruments offer accurate measurements of voltage‚ current‚ and resistance‚ alongside continuity testing and diode checks.
Further capabilities include frequency and capacitance measurements‚ expanding the multimeter’s versatility. The Auto Hold function automatically captures and displays stable readings‚ simplifying measurement processes. The Fluke 87 is designed for field service‚ offering a rugged build and reliable performance.
Specifications include a wide measurement range and high resolution. Detailed technical specifications are available within the Fluke 87 Service Manual (PDF)‚ providing in-depth information for advanced users and technicians. The series is known for its precision and dependability.
Safety Information and Compliance (IEC 348‚ IEC 1010)
The Fluke 83‚ 85‚ and 87 Multimeters are meticulously designed and rigorously tested to adhere to IEC Publication 348‚ outlining safety requirements for electronic measuring apparatus. Crucially‚ these instruments also comply with IEC-1010 safety standards‚ ensuring a high level of user protection during operation.
Compliance with IEC-1010 Category III‚ with a 1000V fuse rating‚ signifies the multimeter’s ability to safely handle potentially hazardous voltage levels. Users should always observe standard electrical safety precautions when working with live circuits. Proper fuse replacement‚ as detailed in the service manual‚ is vital for maintaining safety.
The Fluke 87 series is engineered to minimize risks‚ but responsible usage and adherence to safety guidelines are paramount. Refer to the complete Fluke 87 Service Manual PDF for comprehensive safety instructions and warnings.
Accessing the Fluke 87 Service Manual (PDF)
Obtaining the Fluke 87 Service Manual in PDF format is crucial for detailed repair information and schematics. A 108-page document‚ titled Fluke_83_85_87_Service_Manual.pdf‚ is available online and serves as a valuable reference‚ even if it’s not specifically the 87 III version.
This comprehensive PDF contains schematics and technical details essential for troubleshooting and servicing the instrument. While a direct link isn’t provided here‚ searching online using the file name will yield results. The Fluke website or various electronics forums often host copies.
For official access and support‚ contacting Fluke directly or locating a nearby Fluke Service Center is recommended. The PDF is approximately 613.8 KB in size and covers a wide range of service procedures‚ making it an indispensable resource for technicians.
Fluke 87 Manual Contents Overview
The Fluke 87 manual‚ encompassing both the user guide and service manual‚ provides a thorough understanding of the multimeter’s operation and maintenance. The user manual focuses on mastering the product’s functions and capabilities‚ offering complete operating instructions for everyday use.

The service manual‚ a more detailed 38-page PDF‚ delves into schematics and technical specifics‚ aiding in troubleshooting and repair. It covers safety requirements aligned with IEC Publication 348 and IEC 1010 standards‚ ensuring compliance and safe operation.
Key areas covered include basic operation (powering on/off‚ range selection)‚ measurement functions (voltage‚ current‚ resistance)‚ continuity testing‚ diode checks‚ frequency‚ and capacitance measurements. Fuse replacement procedures and calibration guidance are also included‚ alongside information on the Auto Hold function.
Basic Operation: Powering On/Off & Range Selection
Initiating operation with the Fluke 87 is straightforward. The manual details the power-on sequence‚ typically achieved via a rotary switch. To power off‚ simply return the switch to the ‘OFF’ position. Understanding the rotary switch is crucial for selecting the desired measurement function – voltage‚ current‚ resistance‚ and more.
Range selection is a key aspect of accurate measurements. The Fluke 87 offers both manual and auto-ranging capabilities. Manual ranging requires the user to select the appropriate range for the expected value‚ while auto-ranging automatically adjusts to find the best range.

The user manual provides guidance on interpreting the display and understanding the units of measurement. Proper range selection‚ as outlined in the Fluke 87 manual‚ is vital for obtaining precise and reliable readings.
Measurement Functions: Voltage‚ Current‚ Resistance
The Fluke 87 excels in fundamental electrical measurements. For voltage‚ the manual details procedures for both AC and DC voltage readings‚ specifying appropriate input terminals and range selection. Current measurements‚ similarly‚ cover both AC and DC‚ with cautions regarding proper fuse protection – crucial information detailed within the service manual.
Resistance measurement utilizes the ohmmeter function‚ requiring the circuit to be de-energized. The Fluke 87 manual emphasizes this safety precaution. Accurate resistance readings depend on selecting the correct range and ensuring no external voltage influences the measurement.
The comprehensive guide explains how to interpret readings on the display‚ including units and potential error indicators. Mastering these functions‚ as described in the Fluke 87 manual‚ is essential for effective troubleshooting and electrical analysis.
Continuity Testing and Diode Check
The Fluke 87’s continuity testing function provides a quick assessment of closed circuits. The user manual instructs to connect the test leads across the circuit points and listen for the audible beep‚ indicating a low-resistance path. This is invaluable for identifying broken wires or faulty connections.

The diode check function allows verification of diode functionality. Applying a forward voltage will display the forward voltage drop‚ while a reverse voltage will show “OL” (Overload)‚ indicating an open circuit. The Fluke 87 service manual details expected voltage drops for common diodes.
Proper technique‚ as outlined in the manual‚ involves ensuring the circuit is de-energized before testing. Understanding these functions‚ detailed in the Fluke 87 manual‚ is vital for component-level troubleshooting and circuit verification.
Frequency and Capacitance Measurements
The Fluke 87 multimeter offers both frequency and capacitance measurement capabilities. For frequency‚ the manual details selecting the Hz or kHz range and connecting the test leads to the signal source. The display will then show the frequency of the applied signal‚ crucial for analyzing waveforms and timing circuits.
Capacitance measurements require discharging the capacitor before testing to ensure accurate readings. The user manual instructs selecting the appropriate capacitance range (pF‚ nF‚ µF) and connecting the leads. The Fluke 87 then displays the capacitance value‚ aiding in component verification.
The service manual emphasizes the importance of selecting the correct range for optimal accuracy. These functions‚ thoroughly explained in the Fluke 87 manual‚ are essential for electronics repair and design.
Using the Auto Hold Function
The Fluke 87’s Auto Hold function automatically captures and displays stable readings‚ simplifying measurements where values fluctuate. When activated‚ the multimeter continuously monitors the input signal and only displays a reading when it stabilizes within a defined tolerance. This eliminates the need for constant visual monitoring of the display.
The user manual explains that Auto Hold is particularly useful when measuring signals in noisy environments or when the user’s attention is diverted. It’s activated via a dedicated button on the front panel. The displayed reading is then ‘frozen’ until a more stable value is detected or the button is pressed again.
The Fluke 87 service manual highlights that Auto Hold enhances efficiency and reduces errors‚ ensuring accurate data capture. It’s a key feature for quick and reliable troubleshooting.
Troubleshooting Common Issues
The Fluke 87 service manual details several common issues and their resolutions. A frequent problem is a blown fuse‚ easily addressed with the correct replacement (refer to the fuse replacement section). Display issues‚ such as dim readings‚ often indicate low battery power – simply replace the batteries.
If the multimeter fails to power on‚ verify battery installation and fuse integrity. Intermittent readings can stem from loose test leads or a dirty connector; ensure secure connections and clean contacts. The manual emphasizes checking the test leads for damage before assuming an internal fault.
For more complex problems‚ the Fluke service center network offers expert repair services. Remember to consult the safety information before attempting any internal repairs. If stuck‚ the PDF service manual provides schematics for advanced troubleshooting.
Fuse Replacement Procedures
Important Safety Note: Always disconnect test leads and power off the Fluke 87 before attempting fuse replacement. The service manual stresses using only Fluke-approved replacement fuses to maintain safety and accuracy. Incorrect fuses can pose a serious hazard.

Accessing the fuse requires removing the rear panel. Carefully unscrew and lift the panel. Locate the fuse holder; the manual details its position. Gently remove the old fuse and note its rating (critical for replacement!). Insert the new fuse of the exact same rating.
Ensure the fuse is fully seated in the holder. Replace the rear panel and secure it with the screws. A blown fuse typically indicates an overload condition; investigate the cause before resuming operation. Refer to the schematics in the service manual for detailed diagrams.
Calibration and Maintenance
Maintaining the Fluke 87’s accuracy requires periodic calibration. Fluke recommends annual calibration‚ or more frequently if used in demanding environments. Calibration should be performed by a qualified technician using appropriate standards and procedures detailed in the service manual.
Regular maintenance includes keeping the meter clean. Wipe the exterior with a damp cloth; avoid abrasive cleaners. Inspect the test leads for damage and replace them if necessary. Check battery condition regularly‚ as low battery levels can affect readings.
The service manual provides detailed procedures for internal cleaning and adjustments. However‚ these should only be attempted by trained personnel. Proper calibration ensures the Fluke 87 continues to meet its published specifications‚ guaranteeing reliable measurements.
Fluke 87 Series IV Specifics
The Fluke 87 Series IV (Part Number 676137 5-99) represents an evolution of the popular Fluke 87 multimeter. This iteration incorporates enhancements for improved performance and reliability. It maintains compliance with IEC-1010 Category III‚ featuring a 1000V fuse rating for enhanced safety in various electrical environments.
Key distinctions of the Series IV include refined internal components and potentially updated firmware. Users should consult the dedicated Series IV service manual for specific troubleshooting and calibration procedures‚ as they may differ from earlier models. The PDF service manual provides detailed schematics and technical information.
This version continues to offer the core functionality users expect from the Fluke 87‚ while benefiting from improvements in design and manufacturing processes. It’s a robust tool for professional electricians and technicians.

Locating Fluke Service Centers
For professional repair‚ calibration‚ or maintenance of your Fluke 87 multimeter‚ accessing an authorized Fluke Service Center is crucial. Fluke maintains a global network of certified technicians equipped to handle all aspects of Fluke instrument service.
To find the nearest Fluke Service Center‚ the most reliable method is to contact Fluke directly. You can reach them by phone to inquire about local service options. Alternatively‚ Fluke’s official website provides a service center locator tool‚ allowing you to search by location.
Using an authorized service center ensures that your Fluke 87 is repaired with genuine Fluke parts and according to Fluke’s stringent quality standards‚ preserving its accuracy and reliability. Avoid unauthorized repairs‚ which may void your warranty.
Downloading the Fluke 83/85/87 Service Manual
Accessing the Fluke 83‚ 85‚ and 87 Service Manual in PDF format is readily available online‚ offering detailed schematics and technical information for repair and maintenance. A 108-page document‚ Fluke_83_85_87_Service_Manual.pdf‚ is a valuable resource‚ though it may not be specifically the 87 III version‚ it serves as a useful reference.

This comprehensive manual covers a wide range of troubleshooting procedures‚ component layouts‚ and calibration steps. It’s particularly helpful for technicians and experienced users undertaking repairs. While finding a direct download link can vary‚ searching online using the file name often yields results.
Remember to verify the source of the PDF to ensure it’s a legitimate Fluke document. This manual is essential for understanding the internal workings of these popular multimeters and performing effective service.
Schematics and Technical Details (Reference Manual)
The Fluke 87 Service Manual provides crucial schematics and detailed technical information essential for advanced troubleshooting and repair. This 108-page PDF document‚ often found online as Fluke_83_85_87_Service_Manual.pdf‚ outlines the internal circuitry and component interactions of the multimeter.
Within the manual‚ you’ll discover comprehensive block diagrams‚ circuit board layouts‚ and component-level details. These schematics are invaluable for tracing signal paths‚ identifying faulty components‚ and understanding the meter’s operational principles. The manual also details the safety requirements‚ adhering to IEC Publication 348 and IEC-1010 standards.
Understanding these technical details allows for precise calibration and maintenance‚ ensuring the Fluke 87 continues to deliver accurate and reliable measurements. It’s a vital resource for experienced technicians and those seeking a deep understanding of the instrument’s functionality.